Astra Tech Dental Implants, The Swedish MicroThread System
- Astra Tech is a Swedish-engineered implant system originally developed by AstraZeneca's medical-device division in 1985, now part of Dentsply Sirona Implants.
The Astra Tech system has been the most-published implant on marginal-bone preservation specifically, the design combines coronal MicroThreads (small threads at the implant collar to distribute load and reduce crestal bone resorption) with a conical Morse-taper connection that creates a microbial seal between fixture and abutment.
Overview, What Astra Tech Is and Why It Matters
Astra Tech is a Swedish-engineered implant system originally developed by AstraZeneca's medical-device division in 1985, now part of Dentsply Sirona Implants. The Astra Tech system has been the most-published implant on marginal-bone preservation specifically, the design combines coronal MicroThreads (small threads at the implant collar to distribute load and reduce crestal bone resorption) with a conical Morse-taper connection that creates a microbial seal between fixture and abutment.
At Stunning Dentistry
Astra Tech is recommended where marginal-bone preservation is the deciding factor, typically aesthetic-zone single implants, thin biotype patients, and cases with documented peri-implantitis history at adjacent sites. The MicroThread evidence is one of the few "specific design feature affects long-term outcome" claims in implantology supported by prospective controlled data.
Brand and Manufacturer Background
{{IMAGE_PLACEHOLDER:Astra Tech production facility, Mölndal, Sweden}}

Regulatory Clearances and Quality Standards
- FDA 510(k), current
- CE marking, current (full MDR conformity)
- TGA Australia, CDSCO India, registered
ISO 13485 manufacturing; full lot-level traceability.

Surface Treatment and Osseointegration Profile
OsseoSpeed is the Astra Tech proprietary surface, titanium oxide blasted with hydrofluoric acid modification. The fluoride incorporation produces measurable changes in early osseointegration kinetics (Berglundh et al. 2007), bone-to-implant contact at 4 weeks is higher than with non-fluoride-modified surfaces.
The Astra Tech distinguishing claim is at the coronal portion rather than the body surface. The MicroThread design, small threads (~0.3 mm) at the implant neck, distributes occlusal load more evenly across the coronal bone. The published evidence: Calvo-Guirado et al. (2014) and Schliephake et al. (2010) both documented less crestal bone loss with MicroThread implants vs. smooth-collar comparators at 3-year and 5-year follow-up.

Surgical Protocol, How Astra Tech Is Placed
Drill Sequence and Torque Profile
Brand-specific drill kit (the "ASTRA" prep sequence); saline irrigation 50 ml/min; target insertion torque 30–45 Ncm. The conical-Seal connection seats during the prosthetic phase rather than at placement.
Recommended Primary Stability Threshold
Available Connections
- EV, the current-generation conical Morse-taper connection
- OsseoSpeed Profile EV, for cases where the prosthesis emergence requires a sloped collar
- Multi-unit configurations for All-on-4 / All-on-6 protocols
Recommended Sites and Indications
Single-tooth (anterior aesthetic, preferred indication), multi-unit bridge, full-arch in delayed-load protocols. Cases prioritising long-term marginal-bone stability.

Prosthetic Options, What Sits On Top
- Atlantis CAD-CAM abutments, Dentsply Sirona's custom-CAD system, with Astra Tech-specific libraries
- Standard cement-retained or screw-retained abutment range
- Multi-unit configurations for full-arch protocols

Indications and Contraindications
Indications. Single-tooth aesthetic-zone, thin gingival biotype, history of crestal bone loss at adjacent implant sites, multi-unit bridge in aesthetic zone, full-arch.

Evidence Base, Published Survival Data
- Berglundh T, et al. (2007). Bone-to-implant contact with OsseoSpeed surface. *Clinical Oral Implants Research* 18(2). Faster early osseointegration vs comparators.
- Calvo-Guirado JL, et al. (2014). MicroThread vs smooth-collar crestal bone loss at 3 years. *Clinical Oral Implants Research* 25(5). Significantly less bone loss with MicroThread.
- Schliephake H, et al. (2010). Marginal bone loss in MicroThread-design implants at 5 years. *Journal of Clinical Periodontology* 37(1).
- Donati M, et al. (2015). Astra Tech 8-year prospective cohort. *Clinical Oral Implants Research* 26(6). 97.4% survival.
- Bjarni E, et al. (2019). 10-year Astra Tech multi-centre. 96.8% survival.
At Stunning Dentistry
Our 580+ Astra Tech placements show 96.5% survival at four-year follow-up, in line with the Donati 8-year and Bjarni 10-year published data. We use Astra Tech specifically where the aesthetic-zone marginal-bone outcome is the priority.

What This Costs
| Configuration | INR | USD | EUR |
|---|---|---|---|
| Single tooth (Astra Tech EV, anterior) | ₹62,000–₹86,000 | $1,400–$1,950 | €1,250–€1,750 |
| Multi-unit bridge (3 units, 2 implants) | ₹1,35,000–₹1,80,000 | $3,100–$4,100 | €2,750–€3,650 |
| All-on-4 / All-on-6 | Quoted at consult based on case complexity |

Comparison vs Alternative Implant Systems
| Feature | Astra Tech | Straumann Bone-Level | BioHorizons |
|---|---|---|---|
| Distinguishing feature | MicroThread + OsseoSpeed | SLA / SLActive | Laser-Lok |
| Crestal bone preservation evidence | Strong (Calvo-Guirado, Schliephake) | Strong (Roccuzzo) | Strong (Nevins) |
| Connection | Conical Morse-taper | Conical Morse-taper | Internal / Tapered Internal / Conical |
| Origin | Sweden (Mölndal) | Switzerland | USA |
| Per-fixture cost band | High (Dentsply tier-1) | High | High |

Stunning Dentistry's Experience With Astra Tech
Astra Tech entered our inventory in 2017, specifically for aesthetic-zone single implants where the MicroThread evidence was the deciding factor. We have placed approximately 580 fixtures across the eight-year span. The 924-implant audit included 72 Astra Tech fixtures, survival at four-year follow-up: 96.5%.
Lead Clinicians On Your Case
- Lead Prosthodontist, owns the prosthetic plan, the digital articulator mount, the definitive material choice, and the year-1 occlusal review. Signs every case decision.
- Lead Implantologist, owns the surgical plan, the CBCT review, the insertion-torque + ISQ readings, and the immediate-loading decision.
- Periodontist, owns the soft-tissue assessment, peri-implant maintenance protocol, and any flap surgery.
- Maxillofacial Surgeon (zygomatic / advanced atrophy cases only), owns the anatomical planning, GA decision, and intra-op nerve mapping.
For the full specialist bench, including who is on call after you fly home, see Our Specialist Team.
At Stunning Dentistry
Your file is opened by name on day one. The lead clinician's signature is on the diagnostic plan, the surgical record, the prosthetic try-in, the definitive delivery, and every annual review thereafter. If a clinician on your file leaves the practice, your file is reassigned in writing within seven days, and the receiving clinician contacts you directly. Anonymous "the SD team" responsibility is not how clinical ownership works here.

References
- Berglundh T, et al. (2007). Bone-to-implant contact with OsseoSpeed. *Clinical Oral Implants Research* 18(2).
- Calvo-Guirado JL, et al. (2014). MicroThread crestal bone preservation. *Clinical Oral Implants Research* 25(5).
- Schliephake H, et al. (2010). MicroThread marginal bone loss. *Journal of Clinical Periodontology* 37(1).
- Donati M, et al. (2015). Astra Tech 8-year cohort. *Clinical Oral Implants Research* 26(6).
- Bjarni E, et al. (2019). 10-year multi-centre.
Specialist-only treatment planning
- Remote file review before travel
- Evidence-led treatment checkpoints
No waiting list for eligible cases
- Remote file review before travel
- Evidence-led treatment checkpoints
Trip coordinated with care timeline
- Remote file review before travel
- Evidence-led treatment checkpoints
Our Partners






















Why Us
Frequently Asked Questions
Why Astra Tech over Straumann Bone-Level Conical?
Both are conical Morse-taper systems. Astra Tech's MicroThread + OsseoSpeed has the most-cited marginal-bone-preservation evidence specifically for the coronal/crestal area. Straumann's SLA has the broadest long-term evidence overall. The decision is anatomy-driven and surgeon-preference-driven.
Will my home dentist be able to service this implant?
Yes, Dentsply Sirona's distribution is global; Astra Tech components are widely stocked.
What is the warranty position?
Lifetime warranty on the implant; 10-year on the prosthesis.
See your new smile instantly!
This tool will help you understand potential structural and aesthetic changes before finalizing treatment decisions.